Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21.322
Filtrar
1.
Respir Res ; 25(1): 179, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38664685

RESUMEN

BACKGROUND: Prolonged weaning from mechanical ventilation is associated with poor clinical outcome. Therefore, choosing the right moment for weaning and extubation is essential. Electrical Impedance Tomography (EIT) is a promising innovative lung monitoring technique, but its role in supporting weaning decisions is yet uncertain. We aimed to evaluate physiological trends during a T-piece spontaneous breathing trail (SBT) as measured with EIT and the relation between EIT parameters and SBT success or failure. METHODS: This is an observational study in which twenty-four adult patients receiving mechanical ventilation performed an SBT. EIT monitoring was performed around the SBT. Multiple EIT parameters including the end-expiratory lung impedance (EELI), delta Tidal Impedance (ΔZ), Global Inhomogeneity index (GI), Rapid Shallow Breathing Index (RSBIEIT), Respiratory Rate (RREIT) and Minute Ventilation (MVEIT) were computed on a breath-by-breath basis from stable tidal breathing periods. RESULTS: EELI values dropped after the start of the SBT (p < 0.001) and did not recover to baseline after restarting mechanical ventilation. The ΔZ dropped (p < 0.001) but restored to baseline within seconds after restarting mechanical ventilation. Five patients failed the SBT, the GI (p = 0.01) and transcutaneous CO2 (p < 0.001) values significantly increased during the SBT in patients who failed the SBT compared to patients with a successful SBT. CONCLUSION: EIT has the potential to assess changes in ventilation distribution and quantify the inhomogeneity of the lungs during the SBT. High lung inhomogeneity was found during SBT failure. Insight into physiological trends for the individual patient can be obtained with EIT during weaning from mechanical ventilation, but its role in predicting weaning failure requires further study.


Asunto(s)
Impedancia Eléctrica , Tomografía , Desconexión del Ventilador , Humanos , Desconexión del Ventilador/métodos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Tomografía/métodos , Monitoreo Fisiológico/métodos , Adulto , Respiración Artificial/métodos , Respiración , Anciano de 80 o más Años , Pulmón/fisiopatología , Pulmón/diagnóstico por imagen , Pulmón/fisiología
2.
BMC Public Health ; 24(1): 1079, 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38637778

RESUMEN

BACKGROUND: Low relative fat free mass (FFM) is associated with a greater risk of chronic diseases and mortality. Unfortunately, FFM is currently not being measured regularly to allow for individuals therapy. OBJECTIVE: One reason why FFM is not being used may be related to additional equipment and resources, thus we aimed to identify easily accessible anthropometric markers related with FFM. MATERIALS AND METHODS: We analyzed data of 1,593 individuals (784 women; 49.2%, age range 28-88 years) enrolled in the population-based Study of Health in Pomerania (SHIP-TREND 1). Forty-seven anthropometric markers were derived from a 3D optical body-scanner. FFM was assessed by bioelectrical impedance analysis (FFMBIA) or air displacement plethysmography (FFMADP). In sex-stratified linear regression models, FFM was regressed on anthropometric measurements adjusted for body height and age. Anthropometric markers were ranked according to the coefficient of determination (R2) derived from these regression models. RESULTS: Circumferences of high hip, belly, middle hip, waist and high waist showed the strongest inverse associations with FFM. These relations were stronger in females than in males. Associations of anthropometric markers with FFMAPD were greater compared to FFMBIA. CONCLUSION: Anthropometric measures were more strongly associated with FFMADP compared to FFMBIA. Anthropometric markers like circumferences of the high or middle hip, belly or waist may be appropriate surrogates for FFM to aid in individualized therapy. Given that the identified markers are representative of visceral adipose tissue, the connection between whole body strength as surrogate for FFM and fat mass should be explored in more detail.


Asunto(s)
Composición Corporal , Estatura , Masculino , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Antropometría , Investigación , Índice de Masa Corporal , Impedancia Eléctrica
3.
ACS Sens ; 9(4): 2149-2155, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38579117

RESUMEN

Real-time tracking of respiratory patterns provides noninvasive and quick access for evaluating pathophysiological conditions yet remains challenging due to limited temporal resolution and poor sensitivity to dig out fingerprints of respiratory waveforms. Here, we report an electrochemical sensor for accurately tracing respiratory patterns of small animal models based on the electrochemical impedance mechanism for wireless coupling of a graphdiyne oxide (GYDO)-modified sensing coil chip and a reader coil chip via near-field magnetic induction. In the electrochemical impedance measurement mode, an alternating current is applied through the reader coil chip to perturb proton transport at the GYDO interface of the sensing coil chip. As demonstrated, a high-frequency perturbing condition significantly reduces the interfacial resistance for proton transport by 5 orders of magnitude under 95% relative humidity (RH) and improves the low-humidity responses with a limit of detection down to 0.2% RH, enabling in vivo accurate profiling of respiratory patterns on epileptic rats. The electrochemical impedance coupling system holds great potential for new wireless bioelectronics.


Asunto(s)
Técnicas Electroquímicas , Animales , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Ratas , Grafito/química , Respiración , Ratas Sprague-Dawley , Impedancia Eléctrica , Epilepsia/diagnóstico
4.
Biosensors (Basel) ; 14(4)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38667197

RESUMEN

Microfluidic impedance cytometry (MIC) has emerged as a popular technique for single-cell analysis. Traditional MIC electrode designs consist of a pair of (or three) working electrodes, and their detection performance needs further improvements for microorganisms. In this study, we designed an 8-electrode MIC device in which the center pair was defined as the working electrode, and the connection status of bypass electrodes could be changed. This allowed us to compare the performance of layouts with no bypasses and those with floating or grounding electrodes by simulation and experiment. The results of detecting Φ 5 µm beads revealed that both the grounding and the floating electrode outperformed the no bypass electrode, and the grounding electrode demonstrated the best signal-to-noise ratio (SNR), coefficient of variation (CV), and detection sensitivity. Furthermore, the effects of different bypass grounding areas (numbers of grounding electrodes) were investigated. Finally, particles passing at high horizontal positions can be detected, and Φ 1 µm beads can be measured in a wide channel (150 µm) using a fully grounding electrode, with the sensitivity of bead volume detection reaching 0.00097%. This provides a general MIC electrode optimization technology for detecting smaller particles, even macromolecular proteins, viruses, and exosomes in the future.


Asunto(s)
Impedancia Eléctrica , Electrodos , Relación Señal-Ruido , Microfluídica , Técnicas Biosensibles , Diseño de Equipo , Citometría de Flujo , Técnicas Analíticas Microfluídicas
5.
Physiol Meas ; 45(4)2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38624240

RESUMEN

Objective.Electrical impedance tomography (EIT) is a noninvasive imaging method whereby electrical measurements on the periphery of a heterogeneous conductor are inverted to map its internal conductivity. The EIT method proposed here aims to improve computational speed and noise tolerance by introducing sensitivity volume as a figure-of-merit for comparing EIT measurement protocols.Approach.Each measurement is shown to correspond to a sensitivity vector in model space, such that the set of measurements, in turn, corresponds to a set of vectors that subtend a sensitivity volume in model space. A maximal sensitivity volume identifies the measurement protocol with the greatest sensitivity and greatest mutual orthogonality. A distinguishability criterion is generalized to quantify the increased noise tolerance of high sensitivity measurements.Main result.The sensitivity volume method allows the model space dimension to be minimized to match that of the data space, and the data importance to be increased within an expanded space of measurements defined by an increased number of contacts.Significance.The reduction in model space dimension is shown to increasecomputational efficiency, accelerating tomographic inversion by several orders of magnitude, while the enhanced sensitivitytolerates higher noiselevels up to several orders of magnitude larger than standard methods.


Asunto(s)
Algoritmos , Tomografía Computarizada por Rayos X , Impedancia Eléctrica , Tomografía/métodos , Conductividad Eléctrica
6.
Physiol Meas ; 45(4)2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38565126

RESUMEN

Objective.The objective of this study was to propose a novel data-driven method for solving ill-posed inverse problems, particularly in certain conditions such as time-difference electrical impedance tomography for detecting the location and size of bubbles inside a pipe.Approach.We introduced a new layer architecture composed of three paths: spatial, spectral, and truncated spectral paths. The spatial path processes information locally, whereas the spectral and truncated spectral paths provide the network with a global receptive field. This unique architecture helps eliminate the ill-posedness and nonlinearity inherent in the inverse problem. The three paths were designed to be interconnected, allowing for an exchange of information on different receptive fields with varied learning abilities. Our network has a bottleneck architecture that enables it to recover signal information from noisy redundant measurements. We named our proposed model truncated spatial-spectral convolutional neural network (TSS-ConvNet).Main results.Our model demonstrated superior accuracy with relatively high resolution on both simulation and experimental data. This indicates that our approach offers significant potential for addressing ill-posed inverse problems in complex conditions effectively and accurately.Significance.The TSS-ConvNet overcomes the receptive field limitation found in most existing models that only utilize local information in Euclidean space. We trained the network on a large dataset covering various configurations with random parameters to ensure generalization over the training samples.


Asunto(s)
Tomografía Computarizada por Rayos X , Tomografía , Tomografía/métodos , Impedancia Eléctrica , Redes Neurales de la Computación , Procesamiento de Imagen Asistido por Computador/métodos
7.
Zhonghua Yi Xue Za Zhi ; 104(15): 1247-1252, 2024 Apr 16.
Artículo en Chino | MEDLINE | ID: mdl-38637164

RESUMEN

Acute respiratory distress syndrome (ARDS) is a common and critical clinical condition characterized by diffuse damage to the lung interstitium, alveoli, and increased permeability of pulmonary blood vessels. CT can be used to assess the imaging features, severity, and prediction of ARDS, but it requires patient transportation to the CT room and is only a static examination. Electrical impedance tomography (EIT) is an increasingly widely used monitoring tool in clinical applications in recent years. It enables continuous real-time assessment of lung ventilation distribution at the bedside and has high clinical value in optimizing mechanical ventilation parameters for critically ill patients. This article introduces the basic principles of EIT and how to better utilize EIT technology to guide mechanical ventilation treatment for ARDS patients.


Asunto(s)
Respiración Artificial , Síndrome de Dificultad Respiratoria , Humanos , Respiración Artificial/métodos , Impedancia Eléctrica , Tomografía/métodos , Síndrome de Dificultad Respiratoria/terapia , Tomografía Computarizada por Rayos X/métodos , Pulmón
8.
Sensors (Basel) ; 24(7)2024 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-38610243

RESUMEN

In this paper, we present the development and the validation of a novel index of nociception/anti-nociception (N/AN) based on skin impedance measurement in time and frequency domain with our prototype AnspecPro device. The primary objective of the study was to compare the Anspec-PRO device with two other commercial devices (Medasense, Medstorm). This comparison was designed to be conducted under the same conditions for the three devices. This was carried out during total intravenous anesthesia (TIVA) by investigating its outcomes related to noxious stimulus. In a carefully designed clinical protocol during general anesthesia from induction until emergence, we extract data for estimating individualized causal dynamic models between drug infusion and their monitored effect variables. Specifically, these are Propofol hypnotic drug to Bispectral index of hypnosis level and Remifentanil opioid drug to each of the three aforementioned devices. When compared, statistical analysis of the regions before and during the standardized stimulus shows consistent difference between regions for all devices and for all indices. These results suggest that the proposed methodology for data extraction and processing for AnspecPro delivers the same information as the two commercial devices.


Asunto(s)
Nocicepción , Propofol , Anestesia General , Impedancia Eléctrica , Remifentanilo
9.
Crit Care ; 28(1): 124, 2024 Apr 16.
Artículo en Inglés | MEDLINE | ID: mdl-38627745

RESUMEN

Extracorporeal Carbon Dioxide Removal (ECCO2R) is used in acute respiratory distress syndrome (ARDS) patients to facilitate lung-protective ventilatory strategies. Electrical Impedance Tomography (EIT) allows individual, non-invasive, real-time, bedside, radiation-free imaging of the lungs, providing global and regional dynamic lung analyses. To provide new insights for future ECCO2R research in ARDS, we propose a potential application of EIT to personalize End-Expiratory Pressure (PEEP) following each reduction in tidal volume (VT), as demonstrated in an illustrative case. A 72-year-old male with COVID-19 was admitted to the ICU for moderate ARDS. Monitoring with EIT was started to determine the optimal PEEP value (PEEPEIT), defined as the intersection of the collapse and overdistention curves, after each reduction in VT during ECCO2R. The identified PEEPEIT values were notably low (< 10 cmH2O). The decrease in VT associated with PEEPEIT levels resulted in improved lung compliance, reduced driving pressure and a more uniform ventilation pattern. Despite current Randomized Controlled Trials showing that ultra-protective ventilation with ECCO2R does not improve survival, the applicability of universal ultra-protective ventilation settings for all patients remains a subject of debate. Inappropriately set PEEP levels can lead to alveolar collapse or overdistension, potentially negating the benefits of VT reduction. EIT facilitates real-time monitoring of derecruitment associated with VT reduction, guiding physicians in determining the optimal PEEP value after each decrease in tidal volume. This original description of using EIT under ECCO2R to adjust PEEP at a level compromising between recruitability and overdistention could be a crucial element for future research on ECCO2R.


Asunto(s)
Respiración con Presión Positiva , Síndrome de Dificultad Respiratoria , Masculino , Humanos , Anciano , Impedancia Eléctrica , Respiración con Presión Positiva/métodos , Pulmón , Tomografía Computarizada por Rayos X , Síndrome de Dificultad Respiratoria/terapia , Volumen de Ventilación Pulmonar , Tomografía/métodos
10.
Sci Rep ; 14(1): 8882, 2024 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-38632263

RESUMEN

Wearable long-term monitoring applications are becoming more and more popular in both the consumer and the medical market. In wearable ECG monitoring, the data quality depends on the properties of the electrodes and on how they interface with the skin. Dry electrodes do not require any action from the user. They usually do not irritate the skin, and they provide sufficiently high-quality data for ECG monitoring purposes during low-intensity user activity. We investigated prospective motion artifact-resistant dry electrode materials for wearable ECG monitoring. The tested materials were (1) porous: conductive polymer, conductive silver fabric; and (2) solid: stainless steel, silver, and platinum. ECG was acquired from test subjects in a 10-min continuous settling test and in a 48-h intermittent long-term test. In the settling test, the electrodes were stationary, whereas both stationary and controlled motion artifact tests were included in the long-term test. The signal-to-noise ratio (SNR) was used as the figure of merit to quantify the results. Skin-electrode interface impedance was measured to quantify its effect on the ECG, as well as to leverage the dry electrode ECG amplifier design. The SNR of all electrode types increased during the settling test. In the long-term test, the SNR was generally elevated further. The introduction of electrode movement reduced the SNR markedly. Solid electrodes had a higher SNR and lower skin-electrode impedance than porous electrodes. In the stationary testing, stainless steel showed the highest SNR, followed by platinum, silver, conductive polymer, and conductive fabric. In the movement testing, the order was platinum, stainless steel, silver, conductive polymer, and conductive fabric.


Asunto(s)
Artefactos , Acero Inoxidable , Humanos , Platino (Metal) , Plata , Estudios Prospectivos , Electrocardiografía/métodos , Impedancia Eléctrica , Electrodos , Polímeros
11.
Undersea Hyperb Med ; 51(1): 71-83, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38615356

RESUMEN

Purpose: Ultrasound imaging is commonly used in decompression research to assess venous gas emboli (VGE) post-dive, with higher loads associated with increased decompression sickness risk. This work examines, for the first time in humans, the performance of a novel electrical impedance spectroscopy technology (I-VED), on possible detection of post-dive bubbles presence and arterial endothelial dysfunction that may be used as markers of decompression stress. Methods: I-VED signals were recorded in scuba divers who performed standardized pool dives before and at set time points after their dives at 35-minute intervals for about two hours. Two distinct frequency components of the obtained signals, Low-Pass Frequency-LPF: 0-0.5 Hz and Band-Pass Frequency-BPF: 0.5-10 Hz, are extracted and respectively compared to VGE presence and known flow-mediated dilation trends for the same dive profile for endothelial dysfunction. Results: Subjects with VGE counts above the median for all subjects were found to have an elevated average LPF compared to subjects with lower VGE counts, although this was not statistically significant (p=0.06), as well as significantly decreased BPF standard deviation post-dive compared to pre-dive (p=0.008). Conclusions: I-VED was used for the first time in humans and operated to provide qualitative in-vivo electrical impedance measurements that may contribute to the assessment of decompression stress. Compared to ultrasound imaging, the proposed method is less expensive, not operator-dependent and compatible with continuous monitoring and application of multiple probes. This study provided preliminary insights; further calibration and validation are necessary to determine I-VED sensitivity and specificity.


Asunto(s)
Embolia Aérea , Enfermedades Vasculares , Humanos , Impedancia Eléctrica , Embolia Aérea/diagnóstico por imagen , Embolia Aérea/etiología , Arterias , Descompresión
12.
Biofabrication ; 16(3)2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38574551

RESUMEN

Conventional gut-on-chip (GOC) models typically represent the epithelial layer of the gut tissue, neglecting other important components such as the stromal compartment and the extracellular matrix (ECM) that play crucial roles in maintaining intestinal barrier integrity and function. These models often employ hard, flat porous membranes for cell culture, thus failing to recapitulate the soft environment and complex 3D architecture of the intestinal mucosa. Alternatively, hydrogels have been recently introduced in GOCs as ECM analogs to support the co-culture of intestinal cells inin vivo-like configurations, and thus opening new opportunities in the organ-on-chip field. In this work, we present an innovative GOC device that includes a 3D bioprinted hydrogel channel replicating the intestinal villi architecture containing both the epithelial and stromal compartments of the gut mucosa. The bioprinted hydrogels successfully support both the encapsulation of fibroblasts and their co-culture with intestinal epithelial cells under physiological flow conditions. Moreover, we successfully integrated electrodes into the microfluidic system to monitor the barrier formation in real time via transepithelial electrical resistance measurements.


Asunto(s)
Hidrogeles , Dispositivos Laboratorio en un Chip , Impedancia Eléctrica , Células Epiteliales , Electrodos
13.
Sensors (Basel) ; 24(7)2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38610511

RESUMEN

Flexible neural probes are attractive emerging technologies for brain recording because they can effectively record signals with minimal risk of brain damage. Reducing the electrode impedance of the probe before recording is a common practice of many researchers. However, studies investigating the impact of low impedance levels on high-quality recordings using flexible neural probes are lacking. In this study, we electrodeposited Pt onto a commercial flexible polyimide neural probe and investigated the relationship between the impedance level and the recording quality. The probe was inserted into the brains of anesthetized mice. The electrical signals of neurons in the brain, specifically the ventral posteromedial nucleus of the thalamus, were recorded at impedance levels of 50, 250, 500 and 1000 kΩ at 1 kHz. The study results demonstrated that as the impedance decreased, the quality of the signal recordings did not consistently improve. This suggests that extreme lowering of the impedance may not always be advantageous in the context of flexible neural probes.


Asunto(s)
Lesiones Encefálicas , Animales , Ratones , Impedancia Eléctrica , Neuronas , Encéfalo , Electricidad
16.
Nutr. hosp ; 41(2): 409-414, Mar-Abr. 2024. ilus, tab, graf
Artículo en Español | IBECS | ID: ibc-232657

RESUMEN

Introducción: el análisis de la composición corporal (CC) es un elemento esencial en la práctica clínica nutricional. La impedancia bioeléctrica es una de las técnicas más utilizadas para estimar la CC. Se han planteado diversos enfoques para disminuir el margen de error que presenta, asegurando su aplicación en todas las poblaciones. Uno de ellos es el uso de vectores de impedancia, mediante el empleo de elipses de tolerancia. Objetivo: comparar los vectores de la muestra con la población italiana y determinar elipses de tolerancia específicas para población universitaria colombiana. Materiales y métodos: estudio observacional de corte transversal en 608 universitarios. La participación fue a conveniencia y voluntaria, entre febrero de 2022 y marzo de 2023. El software BIVA 2002 fue usado para calcular las elipses de tolerancia y BIVA Confidence para comparar los vectores de las elipses con la población italiana a partir de la prueba T2 de Hotelling, que se consideró significativa con p < 0,05. Resultados: las medidas de R/Hy Xc/H fueron mayores en mujeres (420,75 ± 56,012 Ω/m vs. 308,7508 ± 41,81 Ω/m) y (46,15 ± 5,79 Ω/m vs. 39,44 ± 5,01 Ω/m), respectivamente. Los vectores de impedancia se posicionaron sobre los cuadrantes superiores del gráfico RXc, evidenciando diferencias significativas en la distribución de los vectores de composición entre las muestras. Conclusiones: los vectores de los universitarios colombianos fueron diferentes a la población de referencia, por lo que fue necesario determinar las elipses específicas.(AU)


Introduction: body composition (BC) analysis is an essential element in clinical nutritional practice. Bioelectrical impedance is one of the most widely used techniques for estimating BC. Several approaches have been proposed to reduce the margin of error it presents, ensuring its appli- cation in all populations. One of them is the use of impedance vectors, using tolerance ellipses.Objective: to compare the sample vectors with the Italian population and to determine specific tolerance ellipses for the Colombian university population. Materials and methods: observational cross-sectional study in 608 university students. Participation was at convenience and voluntary, betweenFebruary 2022 and March 2023. BIVA 2002 software was used to calculate the tolerance ellipses and BIVA confi dence to compare the vectorsof the ellipses with the Italian population using Hotelling’s T2 test, which was considered as significant at p < 0.05. Results: R/H and Xc/H measurements were higher in females (420.75 ± 56.012 Ω/m vs 308.7508 ± 41.81 Ω/m) and (46.15 ± 5.79 Ω/m vs 39.44 ± 5.01 Ω/m), respectively. The impedance vectors were positioned over the upper quadrants of the RXc plot, evidencing significant differences in the distribution of the composition vectors between samples. Conclusions: the vectors of the Colombian university students were different from the reference population, so it was necessary to determinethe specific ellipses.


Asunto(s)
Humanos , Masculino , Femenino , Vectores de Enfermedades , Impedancia Eléctrica , Antropometría , Valores de Referencia , Composición Corporal , Colombia , Ciencias de la Nutrición , Estudios Transversales
17.
BMC Oral Health ; 24(1): 429, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38584280

RESUMEN

BACKGROUND: Accurate assessment of remaining dentin thickness (RDT) is paramount for restorative decisions and treatment planning of vital teeth to avoid any pulpal injury. This diagnostic accuracy study compared the validity and patient satisfaction of an electrical impedance based device Prepometer™ (Hager & Werken, Duisburg, Germany) versus intraoral digital radiography for the estimation of remaining dentin thickness in carious posterior permanent teeth. METHODS: Seventy patients aged 12-25 years with carious occlusal or proximal permanent vital posterior teeth were recruited. Tooth preparation was performed to receive an adhesive restoration. Pre- and post-excavation RDT were measured radiographically by two calibrated raters using the paralleling periapical technique. Prepometer™ measurements were performed by the operator. Patients rated their satisfaction level with each tool on a 4-point Likert scale and 100 mm visual analog scale (VAS). Inter and intragroup comparisons were analyzed using signed rank test, while agreement between devices and observations was tested using weight kappa (WK) coefficient. RESULTS: the intergroup comparisons showed that, before and after excavation, there was a significant difference between measurements made by both techniques (p < 0.001). After excavation, there was a weak agreement between measurements (WK = 0.2, p < 0.001), whereas before excavation, the agreement was not statistically significant (p = 0.407). Patients were significantly more satisfied with Prepometer™ based on scales and VAS (p < 0.001). CONCLUSION: Prepometer™ could be a viable clinical tool for determining RDT with high patient satisfaction, while radiographs tended to overestimate RDT in relation to the Prepometer™.


Asunto(s)
Caries Dental , Satisfacción del Paciente , Humanos , Impedancia Eléctrica , Intensificación de Imagen Radiográfica , Dentina/diagnóstico por imagen , Caries Dental/diagnóstico por imagen , Caries Dental/terapia
18.
Eur Rev Med Pharmacol Sci ; 28(4): 1282-1288, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38436161

RESUMEN

OBJECTIVE: Population-specific muscle mass cut-off values are recommended for the diagnosis of sarcopenia. In this study, we aimed to determine the appendicular muscle mass index (ASMI) and phase angle (PA) cut-off values for the Turkish population using multi-frequency bioelectrical impedance analysis (mBIA). PATIENTS AND METHODS: A total of 250 healthy volunteers aged 18-40 years were included in the study between September 2020 and December 2021. PA was measured by mBIA, and appendicular skeletal muscle mass (ASM) was calculated by the Sergi formula using the resistance and reactance measurements from mBIA. ASMI was calculated as ASM (kg)/(height in meters)2. Two standard deviations (SD) below the mean values were accepted as cut-off points. RESULTS: 134 women and 116 men were included in the study (26.0±5.6 years). The ASMI cut-offs for men and women were 5.86 and 4.36 kg/m2, respectively. The PA cut-offs were 5.66° in men and 4.38° in women. CONCLUSIONS: The present study reported the ASMI and PA cut-off values specific to the Turkish population using the Sergi formula, which was suggested by the European Working Group on Sarcopenia in Older People (EWGSOP).


Asunto(s)
Sarcopenia , Masculino , Humanos , Femenino , Anciano , Impedancia Eléctrica , Sarcopenia/diagnóstico , Voluntarios Sanos , Músculo Esquelético
19.
J Neurodev Disord ; 16(1): 6, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38429713

RESUMEN

BACKGROUND: Angelman syndrome (AS) is a rare neurodevelopmental disorder characterized by severe intellectual disability, little to no expressive speech, visual and motor problems, emotional/behavioral challenges, and a tendency towards hyperphagia and weight gain. The characteristics of AS make it difficult to measure these children's functioning with standard clinical tests. Feasible outcome measures are needed to measure current functioning and change over time, in clinical practice and clinical trials. AIM: Our first aim is to assess the feasibility of several functional tests. We target domains of neurocognitive functioning and physical growth using the following measurement methods: eye-tracking, functional Near-Infrared Spectroscopy (fNIRS), indirect calorimetry, bio-impedance analysis (BIA), and BOD POD (air-displacement plethysmography). Our second aim is to explore the results of the above measures, in order to better understand the AS phenotype. METHODS: The study sample consisted of 28 children with AS aged 2-18 years. We defined an outcome measure as feasible when (1) at least 70% of participants successfully finished the measurement and (2) at least 60% of those participants had acceptable data quality. Adaptations to the test procedure and reasons for early termination were noted. Parents rated acceptability and importance and were invited to make recommendations to increase feasibility. The results of the measures were explored. RESULTS: Outcome measures obtained with eye-tracking and BOD POD met the definition of feasibility, while fNIRS, indirect calorimetry, and BIA did not. The most important reasons for early termination of measurements were showing signs of protest, inability to sit still and poor/no calibration (eye-tracking specific). Post-calibration was often applied to obtain valid eye-tracking results. Parents rated the BOD POD als most acceptable and fNIRS as least acceptable for their child. All outcome measures were rated to be important. Exploratory results indicated longer reaction times to high salient visual stimuli (eye-tracking) as well as high body fat percentage (BOD POD). CONCLUSIONS: Eye-tracking and BOD POD are feasible measurement methods for children with AS. Eye-tracking was successfully used to assess visual orienting functions in the current study and (with some practical adaptations) can potentially be used to assess other outcomes as well. BOD POD was successfully used to examine body composition. TRIAL REGISTRATION: Registered d.d. 23-04-2020 under number 'NL8550' in the Dutch Trial Register: https://onderzoekmetmensen.nl/en/trial/23075.


Asunto(s)
Síndrome de Angelman , Niño , Humanos , Síndrome de Angelman/complicaciones , Síndrome de Angelman/diagnóstico , Reproducibilidad de los Resultados , Composición Corporal , Pletismografía/métodos , Impedancia Eléctrica
20.
Nutrients ; 16(5)2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38474729

RESUMEN

(1) Background: To estimate resistance, reactance, and phase angle values among moderate preterm infants and their variation according to neonatal and maternal characteristics and nutritional intake. (2) Methods: This was a cohort that evaluated 43 moderate preterm infants using bioelectrical impedance analysis. The study variables included resistance, reactance, and phase angle measurements, in addition to classification of nutritional intake. (3) Results: Mean resistance was 602.0 ± 118.2 Ω, reactance was 57.2 Ω (IQR = 42.6-65.2), and phase angle was 522° (IQR = 4.1-6.6). Lower resistance values were found in the presence of risky pregnancy (532.2 ± 111.9 Ω vs. 650.9 ± 97.9 Ω, p < 0.001) and lower reactance values, in the presence of harmful maternal lifestyle habits at both the first (p = 0.01) and second assessments (p = 0.01). Eight preterm infants were considered to have insufficient nutritional intake (23.5%); 17, sufficient (50.0%) and 9, partially sufficient (26.5%). There was less reactance among preterm infants with insufficient nutritional intake (p < 0.001). (4) Conclusions: The bioelectrical impedance analysis measurements were within the range of values reported in other studies. There was an association between full diet and adequate nutritional intake with higher resistance values, while a lower reactance value was associated with the presence of risky pregnancy and harmful maternal lifestyle.


Asunto(s)
Recien Nacido Prematuro , Unidades de Cuidado Intensivo Neonatal , Lactante , Embarazo , Femenino , Humanos , Recién Nacido , Composición Corporal , Impedancia Eléctrica , Familia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...